USP Class VI Adhesives
USP Class VI Approved Adhesives for Medical Device Applications
Master Bond’s biocompatible adhesives are designed to meet the needs of medical device manufacturers. Compounds withstand various types of sterilization methods.
Master Bond UV15DC80Med One Component UV Curable Epoxy
Categories: Polymer; Adhesive; Thermoset; Epoxy; Epoxy Adhesive

Material Notes: Key Features:
  • Allows for Curing in “Shadowed Out” Areas
  • Cures at Temperatures as Low as 80°C
  • Meets USP Class VI requirements
  • Convenient no mix system
  • Excellent physical strength properties
  • Passes ISO 10993-5 cytotoxicity testing
Product Description: Master Bond UV15DC80Med is a special dual cure epoxy based system that offers a primary cure using UV light along with a secondary heat curing mechanism. This extraordinary compound also meets USP Class VI specifications and passes ISO 10993-5 testing. UV15DC80Med allows for curing areas on parts that do not allow UV light curing because of “shadowing” issues. It is important to note that the heat curing portion of this system can be initiated at the relatively lower temperature of 80°C. This kind of UV system is highly desirable because it allows for rapid fixturing with completion of the cure accomplished by adding heat. As alluded to above, a secondary cure at 80°C is not very common. This curing temperature is desirable because many plastics are sensitive to elevated temperatures above that point. One innovative use of a dual cure UV is to fixture two optically opaque substrates, such as metals, using UV light exposure from a side angle and then completing the cure with heat. UV15DC80Med is a moderate viscosity system. The UV portion of the curing mechanism is cationic in nature. This type of curing system generally imparts lower shrinkage upon curing and is not susceptible to oxygen inhibition. UV15DC80Med has very good temperature resistance along with the capability of withstanding many chemicals including liquid steriliants, radiation and even steam (in the form of autoclaving). As one might expect, it is a first rate electrical insulator. UV15DC80Med has very good adhesion to metals, glass, ceramics and many plastics. The service temperature range is -60°F to +400°F. UV15DC80Med will fully cure with UV light in 5-30 seconds depending upon the intensity of the light, the duration of the exposure and the distance of the light source from the material being cured. Areas that are not cured because of shadowing can be heated at 80°C for 40-60 minutes. Post curing at 125-150°C for 15-30 minutes can increase the Tg from 90°C achieved by straight UV curing to over 125°C. In summary, UV15DC80Med is a one part, fast curing, easy to use system with compelling product properties upon curing and that also meet biocompatibility requirements.

Product Advantages:

  • One component system; no mixing needed
  • Will cure by UV light or heat
  • Dual curing mechanism allows for curing in shadowed out areas and rapid fixturing time
  • No oxygen inhibition
  • Excellent physical strength properties
  • Passes USP Class VI and ISO cytotoxicity standards

Information provided by Master Bond Inc.

Vendors:
Available Properties
  • Viscosity, uncured coating
  • Hardness, Shore D
  • Tensile Strength
  • Tensile Modulus
  • Volume Resistivity
  • Dielectric Constant
  • CTE, linear
  • Maximum Service Temperature, Air
  • Minimum Service Temperature, Air
  • Glass Transition Temp, Tg
  • Refractive Index
  • Shelf Life, in original, unopened containers
  • USP Class VI
  
Property Data

This page displays only the text
of a material data sheet.

To see MatWeb's complete data
sheet for this material (including
material property data, metal
compositions, material suppliers,
etc
), please click the button below.

Manufacturer Notes:
Master Bond Inc.

Category Notes
Plastic

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

 

USP Class VI adhesives
Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.