MatWeb - Material Property Data Advertise with MatWeb!     Register Now
Data sheets for over 180,000 metals, plastics, ceramics, and composites.
MatWeb - Material Property Data HOME  •   SEARCH  •   TOOLS  •   SUPPLIERS  •   FOLDERS  •   ABOUT US  •   FAQ  •   LOG IN    
Recently Viewed Materials (most recent at top)  

Login to see your most recently viewed materials here.

Or if you don't have an account with us yet, then click here to register.

  Searches:   Advanced  | Category  | Property  | Metals  | Trade Name  | Manufacturer  | Recently Viewed Materials
  
Master Bond adhesives
3M 4604 Silicone Rubber Termination Kit
Categories: Polymer; Thermoset; Silicone; Silicone Rubber

Material Notes: 3M™ 4604 and 4605 Quick Term II Silicone Rubber Termination Kits are three-piece Cold Shrink terminations for Tape Shield, Wire Shield, and LC Shield power cables. They meet the requirements of IEEE standard 48-1990, for class 1 terminations. In addition they meet German standard VDE 0278 parts 5 & 100, British standard BS C-89, Spanish standard UNE 21-115-75 and Brazilian standard A-B-N-T-9314. Similar terminations using Quick Term II technology meet French EdF standards HN 33-E-01 and HN 41-E-01. Data on foreign standards are available upon request. The 3M Quick Term II consists of a high dielectric constant (High-K) stress control tube insulated with a molded silicone skirted insulator. The 4600-series termination is a twelve-skirt design incorporating in one-piece base termination assembly, a four-skirt extension insulator, and a Silicone Rubber Jacket-Sealing Cold Shrink PST Assembly. Quick Term II terminations are provided in an expanded state; mounted on a removable inner supporting plastic core. As supplied in this pre-stretched condition and termination is ready for field installation. During installation the core in unwound, allowing the termination to shrink and form a tight seal. Collectively, these termination kits cover cables with primary insulation O.D. from 1.31” to 2.60” (33 to 66 mm). These kits can be used to terminate 46 kV Shielded Power Cables from 4/0 AWG to 1500 kcm.

Information provided by 3M

Vendors:
Available Properties
  • Tensile Strength, Ultimate, ASTM D42-68, Silicone Rubber Insulator
  • Tensile Strength, Ultimate, ASTM D42-68, EPDM Rubber Hi-K Stress Control Tube
  • Dielectric Constant, ASTM D150-70, Silicone Rubber Insulator
  • Dielectric Constant, ASTM D150-70, Silicone Rubber Insulator
  • Dielectric Constant, ASTM D150-70, Silicone Rubber Insulator
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Strength, ASTM D149-70, Silicone Rubber Insulator
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Track Resistance, ASTM 2303-68, 2.5 kV, 10 k Ohms
  
Property Data

This page displays only the text
of a material data sheet.

To see MatWeb's complete data
sheet for this material (including
material property data, metal
compositions, material suppliers,
etc
), please click the button below.

Manufacturer Notes:
none

Category Notes
Plastic

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

 

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.