Ensinger PEI

Melos Mecoline S RDX 1215 F Halogen-free, radiation cross-linkable, flame retardant sheathing
Categories: Polymer; Thermoplastic

Material Notes: Halogen-free, radiation cross-linkable, flame retardant sheathing compound for power and telecommunication cables

Compound class: Sheathing

Compound category: RDX

Flame retardant: ATH

Standards: EN 50264 EM101-104; IEC 60092-360 SHF2; NEK 606

Typical applications: Halogen-free, low smoke, flexible at low temperatures, highly oil and extra fuel resistant, radiation cross-linkable, flame retardant compound for Offshore/Shipboard and Marine/Aerospace applications.

Features: Flame retardant; Halogen-free; Low smoke; High temperature resistant; Oil resistant; Flexible; Flexible at low temperatures

Information provided by Melos

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.60 g/cc0.0578 lb/in³pressed plaques, 165°C / 5 min.; DIN EN ISO 1183-1A
Melt Flow 15 g/10 min
@Load 21.6 kg,
Temperature 175 °C
15 g/10 min
@Load 47.6 lb,
Temperature 347 °F
DIN EN ISO 1133
 
Mechanical PropertiesMetricEnglishComments
Hardness, Shore A 8383pressed plaques, 165°C / 5 min.; DIN ISO 7619-1
 8888cross-linked plaques or tapes, 100kGy; DIN ISO 7619-1
Tensile Strength 8.40 MPa1220 psiextruded tapes; IEC 60811-501
 13.0 MPa1890 psicross-linked plaques or tapes, 100kGy; IEC 60811-501
 6.75 MPa
@Temperature 100 °C,
Time 605000 sec
979 psi
@Temperature 212 °F,
Time 168 hour
cross-linked plaques / tapes, Fluid IRM 903; IEC 60811-404
 7.20 MPa
@Temperature 70.0 °C,
Time 4.838e+6 sec
1040 psi
@Temperature 158 °F,
Time 1344 hour
cross-linked plaques / tapes, EDC 95-11; IEC 60811-404
 7.913 MPa
@Temperature 75.0 °C,
Time 5.18e+6 sec
1148 psi
@Temperature 167 °F,
Time 1440 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 7.93 MPa
@Temperature 100 °C,
Time 86400 sec
1150 psi
@Temperature 212 °F,
Time 24.0 hour
cross-linked plaques / tapes, Fluid IRM 903; IEC 60811-404
 8.324 MPa
@Temperature 70.0 °C,
Time 4.838e+6 sec
1207 psi
@Temperature 158 °F,
Time 1344 hour
cross-linked plaques / tapes, Carbo Sea (oil based); IEC 60811-404
 8.786 MPa
@Temperature 90.0 °C,
Time 605000 sec
1274 psi
@Temperature 194 °F,
Time 168 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 9.467 MPa
@Temperature 121 °C,
Time 605000 sec
1373 psi
@Temperature 250 °F,
Time 168 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 10.06 MPa
@Temperature 100 °C,
Time 86400 sec
1459 psi
@Temperature 212 °F,
Time 24.0 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 10.06 MPa
@Temperature 100 °C,
Time 605000 sec
1459 psi
@Temperature 212 °F,
Time 168 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
Elongation at Break 206 %206 %cross-linked plaques or tapes, 100kGy; IEC 60811-501
 379 %379 %extruded tapes; IEC 60811-501
 5.0 %
@Temperature 200 °C,
Time 900 sec
5.0 %
@Temperature 392 °F,
Time 0.250 hour
Hot set test, Residual, 0.2 Mpa; IEC 60811-507
 15 %
@Temperature 200 °C,
Time 900 sec
15 %
@Temperature 392 °F,
Time 0.250 hour
Hot set test, under load, 0.2 Mpa; IEC 60811-507
 308.5 %
@Temperature 70.0 °C,
Time 4.838e+6 sec
308.5 %
@Temperature 158 °F,
Time 1344 hour
cross-linked plaques / tapes, EDC 95-11; IEC 60811-404
 322.15 %
@Temperature 100 °C,
Time 86400 sec
322.15 %
@Temperature 212 °F,
Time 24.0 hour
cross-linked plaques / tapes, Fluid IRM 903; IEC 60811-404
 328.6 %
@Temperature 100 °C,
Time 605000 sec
328.6 %
@Temperature 212 °F,
Time 168 hour
cross-linked plaques / tapes, Fluid IRM 903; IEC 60811-404
 330.87 %
@Temperature 75.0 °C,
Time 5.18e+6 sec
330.87 %
@Temperature 167 °F,
Time 1440 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 336.55 %
@Temperature 70.0 °C,
Time 4.838e+6 sec
336.55 %
@Temperature 158 °F,
Time 1344 hour
cross-linked plaques / tapes, Carbo Sea (oil based); IEC 60811-404
 342.24 %
@Temperature 90.0 °C,
Time 605000 sec
342.24 %
@Temperature 194 °F,
Time 168 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 371.8 %
@Temperature 121 °C,
Time 605000 sec
371.8 %
@Temperature 250 °F,
Time 168 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 389.99 %
@Temperature 100 °C,
Time 86400 sec
389.99 %
@Temperature 212 °F,
Time 24.0 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 409.32 %
@Temperature 100 °C,
Time 605000 sec
409.32 %
@Temperature 212 °F,
Time 168 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 
Thermal PropertiesMetricEnglishComments
Maximum Service Temperature, Air 125 °C257 °F
Minimum Service Temperature, Air -60.0 °C-76.0 °F
Brittleness Temperature -61.8 °C-79.2 °F100; ASTM D 746-14
 
Processing PropertiesMetricEnglishComments
Processing Temperature 170 - 180 °C338 - 356 °FMaximum mass temperature
 170 - 190 °C338 - 374 °FTool
Zone 1 110 - 130 °C230 - 266 °F
Zone 2 120 - 140 °C248 - 284 °F
Zone 3 130 - 150 °C266 - 302 °F
Zone 4 140 - 160 °C284 - 320 °F
Zone 5 150 - 170 °C302 - 338 °F
Adapter Temperature 60.0 - 180 °C140 - 356 °F
Head Temperature 165 - 185 °C329 - 365 °F
Drying Temperature 60.0 - 70.0 °C140 - 158 °F
Dry Time 4.00 - 6.00 hour4.00 - 6.00 hour
Shelf Life 12.0 Month12.0 Month
 
Component Elements PropertiesMetricEnglishComments
Loss on Ignition(%) 42 %42 %ASTM D 2863 A
 
Descriptive Properties
Main burning properties11700 kJ/kgCaloric Value Hu, DIN 51900-2
Water absorption1,9 mg/cm²Water purified 240h at 70°C, IEC 60811-402

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PMELOS028 / 296135

Visit Zeus Inc. for PEEK Tubing

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.