Master Bond adhesives

3M 4604 Silicone Rubber Termination Kit
Categories: Polymer; Thermoset; Silicone; Silicone Rubber

Material Notes: 3M™ 4604 and 4605 Quick Term II Silicone Rubber Termination Kits are three-piece Cold Shrink terminations for Tape Shield, Wire Shield, and LC Shield power cables. They meet the requirements of IEEE standard 48-1990, for class 1 terminations. In addition they meet German standard VDE 0278 parts 5 & 100, British standard BS C-89, Spanish standard UNE 21-115-75 and Brazilian standard A-B-N-T-9314. Similar terminations using Quick Term II technology meet French EdF standards HN 33-E-01 and HN 41-E-01. Data on foreign standards are available upon request. The 3M Quick Term II consists of a high dielectric constant (High-K) stress control tube insulated with a molded silicone skirted insulator. The 4600-series termination is a twelve-skirt design incorporating in one-piece base termination assembly, a four-skirt extension insulator, and a Silicone Rubber Jacket-Sealing Cold Shrink PST Assembly. Quick Term II terminations are provided in an expanded state; mounted on a removable inner supporting plastic core. As supplied in this pre-stretched condition and termination is ready for field installation. During installation the core in unwound, allowing the termination to shrink and form a tight seal. Collectively, these termination kits cover cables with primary insulation O.D. from 1.31” to 2.60” (33 to 66 mm). These kits can be used to terminate 46 kV Shielded Power Cables from 4/0 AWG to 1500 kcm.

Information provided by 3M

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Mechanical PropertiesMetricEnglishComments
Tensile Strength, Ultimate 8.27 MPa1200 psiSilicone Rubber Insulator; ASTM D42-68
 9.611 MPa1394 psiEPDM Rubber Hi-K Stress Control Tube; ASTM D42-68
 
Electrical PropertiesMetricEnglishComments
Dielectric Constant  2.7
@Temperature 130 °C
2.7
@Temperature 266 °F
Silicone Rubber Insulator; ASTM D150-70
 3.0
@Temperature 90.0 °C
3.0
@Temperature 194 °F
Silicone Rubber Insulator; ASTM D150-70
 3.4
@Temperature 23.0 °C
3.4
@Temperature 73.4 °F
Silicone Rubber Insulator; ASTM D150-70
 20
@Frequency 100000 Hz
20
@Frequency 100000 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 24
@Frequency 10000 Hz
24
@Frequency 10000 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 29
@Frequency 1000 Hz
29
@Frequency 1000 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 35
@Frequency 150 Hz
35
@Frequency 150 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 24.5
@Frequency 60.0 Hz,
Temperature 65.0 °C
24.5
@Frequency 60.0 Hz,
Temperature 149 °F
EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain; ASTM D150-70
 25.2
@Frequency 60.0 Hz,
Temperature 90.0 °C
25.2
@Frequency 60.0 Hz,
Temperature 194 °F
EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain; ASTM D150-70
 25.7
@Frequency 60.0 Hz,
Temperature 23.0 °C
25.7
@Frequency 60.0 Hz,
Temperature 73.4 °F
EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain; ASTM D150-70
 27.2
@Frequency 60.0 Hz,
Temperature 65.0 °C
27.2
@Frequency 60.0 Hz,
Temperature 149 °F
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 27.7
@Frequency 60.0 Hz,
Temperature 90.0 °C
27.7
@Frequency 60.0 Hz,
Temperature 194 °F
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 28.8
@Frequency 60.0 Hz,
Temperature 23.0 °C
28.8
@Frequency 60.0 Hz,
Temperature 73.4 °F
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
Dielectric Strength 20.0 kV/mm
@Thickness 0.190 mm
507 kV/in
@Thickness 0.00750 in
Silicone Rubber Insulator; ASTM D149-70
Dissipation Factor  0.12
@Frequency 100000 Hz
0.12
@Frequency 100000 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 0.14
@Frequency 10000 Hz
0.14
@Frequency 10000 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 0.15
@Frequency 1000 Hz
0.15
@Frequency 1000 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 0.16
@Frequency 150 Hz
0.16
@Frequency 150 Hz
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 0.093
@Frequency 60.0 Hz,
Temperature 65.0 °C
0.093
@Frequency 60.0 Hz,
Temperature 149 °F
EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain; ASTM D150-70
 0.096
@Frequency 60.0 Hz,
Temperature 23.0 °C
0.096
@Frequency 60.0 Hz,
Temperature 73.4 °F
EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain; ASTM D150-70
 0.132
@Frequency 60.0 Hz,
Temperature 90.0 °C
0.132
@Frequency 60.0 Hz,
Temperature 194 °F
EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain; ASTM D150-70
 0.161
@Frequency 60.0 Hz,
Temperature 90.0 °C
0.161
@Frequency 60.0 Hz,
Temperature 194 °F
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 0.165
@Frequency 60.0 Hz,
Temperature 65.0 °C
0.165
@Frequency 60.0 Hz,
Temperature 149 °F
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
 0.166
@Frequency 60.0 Hz,
Temperature 23.0 °C
0.166
@Frequency 60.0 Hz,
Temperature 73.4 °F
EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain; ASTM D150-70
Track Resistance 36000 sec36000 sec2.5 kV, 10 k Ohms; ASTM 2303-68

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

Users viewing this material also viewed the following:
DuPont Mobility and Materials Vespel® ST-2030 DF Polyimide
Overview of materials for Silicone Rubber
Momentive Performance Materials Silplus™ 60 CW Heat Cured Rubber - Cable & Wire
Momentive Performance Materials Silopren™ Electro 242-0 Electrically Insulating Liquid Silicone Rubber
Methanol (CH3OH; Methyl Alcohol)

PMM35163 / 169910

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.