Physical Properties | Original Value | Comments |
---|
Density | 8.23 g/cc |
|
Mechanical Properties | Original Value | Comments |
---|
Tensile Strength, Ultimate | 805 MPa |
| 110 MPa @Temperature 1095 °C |
| 210 MPa @Temperature 980 °C |
| 340 MPa @Temperature 870 °C |
| 470 MPa @Temperature 760 °C |
| 575 MPa @Temperature 650 °C |
| 625 MPa @Temperature 540 °C |
Tensile Strength, Yield | 375 MPa @Strain 0.2 % |
| 60.0 MPa @Strain 0.2 %, Temperature 1095 °C |
| 130 MPa @Strain 0.2 %, Temperature 980 °C |
| 190 MPa @Strain 0.2 %, Temperature 870 °C |
| 200 MPa @Strain 0.2 %, Temperature 760 °C |
| 210 MPa @Strain 0.2 %, Temperature 540 °C |
| 210 MPa @Strain 0.2 %, Temperature 650 °C |
Elongation at Break | 51.4 % |
| 52.6 % @Temperature 760 °C |
| 57.4 % @Temperature 650 °C |
| 60.3 % @Temperature 540 °C |
| 69.1 % @Temperature 870 °C |
| 83.9 % @Temperature 980 °C |
| 95.2 % @Temperature 1095 °C |
Modulus of Elasticity | 205 GPa |
| 138 GPa @Temperature 1000 °C |
| 143 GPa @Temperature 900 °C |
| 148 GPa @Temperature 800 °C |
| 155 GPa @Temperature 700 °C |
| 164 GPa @Temperature 600 °C |
| 172 GPa @Temperature 500 °C |
| 179 GPa @Temperature 400 °C |
| 187 GPa @Temperature 300 °C |
| 195 GPa @Temperature 200 °C |
| 200 GPa @Temperature 100 °C |
Charpy Impact | 240 J |
|
Electrical Properties | Original Value | Comments |
---|
Electrical Resistivity | 0.0000952 ohm-cm |
| 0.0000986 ohm-cm @Temperature 100 °C |
| 0.0001026 ohm-cm @Temperature 200 °C |
| 0.0001065 ohm-cm @Temperature 300 °C |
| 0.0001095 ohm-cm @Temperature 400 °C |
| 0.0001125 ohm-cm @Temperature 500 °C |
| 0.0001151 ohm-cm @Temperature 600 °C |
| 0.0001172 ohm-cm @Temperature 700 °C |
| 0.000119 ohm-cm @Temperature 800 °C |
| 0.0001207 ohm-cm @Temperature 900 °C |
| 0.0001223 ohm-cm @Temperature 1000 °C |
| 0.0001237 ohm-cm @Temperature 1100 °C |
|
Thermal Properties | Original Value | Comments |
---|
CTE, linear | 14.7 µm/m-°C @Temperature 25.0 - 100 °C |
| 14.9 µm/m-°C @Temperature 25.0 - 200 °C |
| 15.1 µm/m-°C @Temperature 25.0 - 300 °C |
| 15.4 µm/m-°C @Temperature 25.0 - 400 °C |
| 15.7 µm/m-°C @Temperature 25.0 - 500 °C |
| 16.1 µm/m-°C @Temperature 25.0 - 600 °C |
| 16.4 µm/m-°C @Temperature 25.0 - 700 °C |
| 16.7 µm/m-°C @Temperature 25.0 - 800 °C |
| 17.0 µm/m-°C @Temperature 25.0 - 900 °C |
| 17.1 µm/m-°C @Temperature 25.0 - 1000 °C |
Specific Heat Capacity | 0.464 J/g-°C |
| 0.475 J/g-°C @Temperature 100 °C |
| 0.493 J/g-°C @Temperature 200 °C |
| 0.508 J/g-°C @Temperature 300 °C |
| 0.523 J/g-°C @Temperature 400 °C |
| 0.538 J/g-°C @Temperature 500 °C |
| 0.552 J/g-°C @Temperature 600 °C |
| 0.561 J/g-°C @Temperature 700 °C |
| 0.570 J/g-°C @Temperature 800 °C |
| 0.595 J/g-°C @Temperature 900 °C |
| 0.618 J/g-°C @Temperature 1000 °C |
| 0.638 J/g-°C @Temperature 1100 °C |
Thermal Conductivity | 11.1 W/m-K |
| 13.1 W/m-K @Temperature 100 °C |
| 15.4 W/m-K @Temperature 200 °C |
| 17.3 W/m-K @Temperature 300 °C |
| 19.0 W/m-K @Temperature 400 °C |
| 20.8 W/m-K @Temperature 500 °C |
| 22.4 W/m-K @Temperature 600 °C |
| 24.0 W/m-K @Temperature 700 °C |
| 25.5 W/m-K @Temperature 800 °C |
| 27.2 W/m-K @Temperature 900 °C |
| 28.9 W/m-K @Temperature 1000 °C |
| 30.4 W/m-K @Temperature 1100 °C |
Melting Point | 1330 - 1415 °C |
Solidus | 1330 °C |
Liquidus | 1415 °C |
|
Component Elements Properties | Original Value | Comments |
---|
Aluminum, Al | 0.20 % |
Carbon, C | 0.10 % |
Chromium, Cr | 22 % |
Cobalt, Co | 18 % |
Iron, Fe | 31 % |
Lanthanum, La | 0.020 % |
Manganese, Mn | 1.0 % |
Molybdenum, Mo | 3.0 % |
Nickel, Ni | 20 % |
Nitrogen, N | 0.20 % |
Silicon, Si | 0.40 % |
Tantalum, Ta | 0.60 % |
Tungsten, W | 2.5 % |
Zirconium, Zr | 0.020 % |
Some of the values displayed above may have been converted from their original units and/or rounded in order to
display the information in a consistent format. Users requiring more precise data for scientific or engineering
calculations can click on the property value to see the original value as well as raw conversions to equivalent units.
We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding
error. We also ask that you refer to MatWeb's
terms of use regarding this information.