Ensinger PEI

(Viewing data as-entered. Click here to return)
DuPont Mobility and Materials Zytel® RS LC1000 BK385 Nylon 1010 (With Extended Stress-Strain Tabular Data)  (discontinued **)
Categories: Polymer; Renewable/Recycled Polymer; Thermoplastic; Nylon (Polyamide PA)

Material Notes: UV Stabilized Renewably Sourced Polyamide 1010 Developed for Extrusion

Zytel RS LC1000 BK385 is a renewable sourced Polyamide 1010 containing a minimum of 90% renewably sourced ingredient by weight. The material is flexible unreinforced UV and heat sta

While this product line has been acquired by Celanese, this specific grade had been disconued while still a DuPont product so it is listed here as a discontinued DuPont product.

Key Words: PA1010
Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesOriginal ValueComments
Density 1.05 g/ccDAM; ISO 1183
Moisture Absorption 1.00 %
@Thickness 2.00 mm
DAM; Sim. to ISO 62
Viscosity Test 130 cm³/gISO 307 1157 1628
Linear Mold Shrinkage, Flow 0.014 cm/cmDAM; ISO 294-4 2577
Linear Mold Shrinkage, Transverse 0.0080 cm/cmDAM; ISO 294-4 2577
 
Mechanical PropertiesOriginal ValueComments
Tensile Strength, Yield 49.0 MPa50%RH; ISO 527-1/-2
 60.0 MPaDAM; ISO 527-1/-2
Tensile Stress at Strain 0.270 MPa
@Strain 0.07 %,
Temperature 150 °C
50%RH; ISO 11403-1 -2
 0.300 MPa
@Strain 0.08 %,
Temperature 150 °C
DAM; ISO 11403-1 -2
 0.450 MPa
@Strain 0.03 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 0.450 MPa
@Strain 0.1 %,
Temperature 90.0 °C
50%RH; ISO 11403-1 -2
 0.480 MPa
@Strain 0.02 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 0.490 MPa
@Strain 0.09 %,
Temperature 90.0 °C
DAM; ISO 11403-1 -2
 0.750 MPa
@Strain 0.04 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 0.840 MPa
@Strain 0.08 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 0.840 MPa
@Strain 0.05 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 0.930 MPa
@Strain 0.02 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 1.03 MPa
@Strain 0.07 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 1.29 MPa
@Strain 0.06 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 1.39 MPa
@Strain 0.05 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 1.70 MPa
@Strain 0.06 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 1.78 MPa
@Strain 0.1 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 1.92 MPa
@Strain 0.11 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 2.85 MPa
@Strain 0.11 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 3.15 MPa
@Strain 0.17 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 3.37 MPa
@Strain 0.14 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 3.69 MPa
@Strain 0.18 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 3.72 MPa
@Strain 0.18 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 4.22 MPa
@Strain 0.25 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 4.37 MPa
@Strain 0.18 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 4.71 MPa
@Strain 0.19 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 4.78 MPa
@Strain 2.86 %,
Temperature 150 °C
50%RH; ISO 11403-1 -2
 5.09 MPa
@Strain 0.23 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 5.35 MPa
@Strain 0.25 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 5.45 MPa
@Strain 0.25 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 5.74 MPa
@Strain 0.23 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 5.84 MPa
@Strain 3.2 %,
Temperature 150 °C
DAM; ISO 11403-1 -2
 6.48 MPa
@Strain 0.43 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 10.0 MPa
@Strain 13.37 %,
Temperature 150 °C
50%RH; ISO 11403-1 -2
 11.04 MPa
@Strain 2.94 %,
Temperature 90.0 °C
DAM; ISO 11403-1 -2
 11.12 MPa
@Strain 14 %,
Temperature 150 °C
DAM; ISO 11403-1 -2
 11.26 MPa
@Strain 24.48 %,
Temperature 150 °C
50%RH; ISO 11403-1 -2
 11.43 MPa
@Strain 70.4 %,
Temperature 150 °C
50%RH; ISO 11403-1 -2
 11.6 MPa
@Strain 100.03 %,
Temperature 150 °C
50%RH; ISO 11403-1 -2
 12.25 MPa
@Strain 25.96 %,
Temperature 150 °C
DAM; ISO 11403-1 -2
 12.31 MPa
@Strain 71.22 %,
Temperature 150 °C
DAM; ISO 11403-1 -2
 12.48 MPa
@Strain 100.05 %,
Temperature 150 °C
DAM; ISO 11403-1 -2
 12.64 MPa
@Strain 4.33 %,
Temperature 90.0 °C
50%RH; ISO 11403-1 -2
 19.82 MPa
@Strain 14.51 %,
Temperature 90.0 °C
50%RH; ISO 11403-1 -2
 19.95 MPa
@Strain 2.38 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 21.17 MPa
@Strain 73.09 %,
Temperature 90.0 °C
50%RH; ISO 11403-1 -2
 21.22 MPa
@Strain 26.5 %,
Temperature 90.0 °C
50%RH; ISO 11403-1 -2
 21.41 MPa
@Strain 13.33 %,
Temperature 90.0 °C
DAM; ISO 11403-1 -2
 21.59 MPa
@Strain 100.03 %,
Temperature 90.0 °C
50%RH; ISO 11403-1 -2
 22.9 MPa
@Strain 72.74 %,
Temperature 90.0 °C
DAM; ISO 11403-1 -2
 22.97 MPa
@Strain 25.83 %,
Temperature 90.0 °C
DAM; ISO 11403-1 -2
 23.42 MPa
@Strain 100.03 %,
Temperature 90.0 °C
DAM; ISO 11403-1 -2
 24.01 MPa
@Strain 1.04 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 30.88 MPa
@Strain 1.41 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 34.21 MPa
@Strain 70.99 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 34.57 MPa
@Strain 100.03 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 36.0 MPa
@Strain 12.5 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 37.15 MPa
@Strain 24.59 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 38.31 MPa
@Strain 68.85 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 39.49 MPa
@Strain 100.05 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 39.52 MPa
@Strain 70.06 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 39.63 MPa
@Strain 100.04 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 40.84 MPa
@Strain 9.98 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 42.52 MPa
@Strain 21.74 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 42.81 MPa
@Strain 71.61 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 43.39 MPa
@Strain 100.04 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 48.1 MPa
@Strain 54.79 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 48.9 MPa
@Strain 79.54 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 49.05 MPa
@Strain 8.61 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 49.85 MPa
@Strain 22.96 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 50.27 MPa
@Strain 38.36 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 50.29 MPa
@Strain 19.74 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 50.47 MPa
@Strain 2.35 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 51.63 MPa
@Strain 43.68 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 52.02 MPa
@Strain 2.65 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 53.44 MPa
@Strain 19.88 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 54.0 MPa
@Strain 27.41 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 54.49 MPa
@Strain 20.94 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 55.41 MPa
@Strain 34.32 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 59.12 MPa
@Strain 6.81 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 66.43 MPa
@Strain 11.77 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 71.91 MPa
@Strain 4.65 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 84.01 MPa
@Strain 18.92 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 89.32 MPa
@Strain 9.59 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 91.05 MPa
@Strain 13.49 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 94.14 MPa
@Strain 7.53 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
Elongation at Break 50 %DAM; Nominal; ISO 527-1/-2
 >= 50 %50%RH; Nominal; ISO 527-1/-2
Elongation at Yield 4.6 %DAM; ISO 527-1/-2
 24 %50%RH; ISO 527-1/-2
Tensile Modulus 1160 MPa50%RH; ISO 527-1/-2
 2100 MPaDAM; ISO 527-1/-2
 295 MPa
@Temperature 120 °C
50%RH; ISO 11403-1 -2
 311 MPa
@Temperature 120 °C
DAM; ISO 11403-1 -2
 886 MPa
@Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 1249 MPa
@Temperature 40.0 °C
DAM; ISO 11403-1 -2
 2388 MPa
@Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 2407 MPa
@Temperature -40.0 °C
DAM; ISO 11403-1 -2
Flexural Modulus 1740 MPaDAM; ISO 178
Secant Modulus 0.0445 GPa
@Strain 76.78 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 0.0509 GPa
@Strain 75.16 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 0.051979 GPa
@Strain 76.05 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 0.0555 GPa
@Strain 77.29 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 0.0644 GPa
@Strain 54.17 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 0.0755 GPa
@Strain 52.11 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 0.0783 GPa
@Strain 54.53 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 0.079326 GPa
@Strain 50.74 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 0.0809 GPa
@Strain 59.71 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 0.108 GPa
@Strain 33.72 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 0.119 GPa
@Strain 40.08 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 0.13477 GPa
@Strain 31.78 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 0.138 GPa
@Strain 30.48 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 0.165 GPa
@Strain 30.98 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 0.172 GPa
@Strain 28.46 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 0.195 GPa
@Strain 25.9 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 0.226 GPa
@Strain 16.33 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 0.233 GPa
@Strain 23.53 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 0.305 GPa
@Strain 13.76 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 0.329 GPa
@Strain 19.64 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 0.412 GPa
@Strain 12.15 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 0.433 GPa
@Strain 17.17 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 0.518 GPa
@Strain 10.94 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 0.538 GPa
@Strain 12.72 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 0.691 GPa
@Strain 11.35 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 0.791 GPa
@Strain 11.24 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 0.838 GPa
@Strain 2.38 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 0.945 GPa
@Strain 8.15 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 1.05 GPa
@Strain 0.08 %,
Temperature 40.0 °C
50%RH; ISO 11403-1 -2
 1.09 GPa
@Strain 8.72 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 1.29 GPa
@Strain 5.1 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 1.47 GPa
@Strain 0.07 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 1.50 GPa
@Strain 0.03 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 1.51 GPa
@Strain 0.43 %,
Temperature 40.0 °C
DAM; ISO 11403-1 -2
 1.53 GPa
@Strain 5.48 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 1.68 GPa
@Strain 0.05 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 1.688 GPa
@Strain 0.25 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 1.72 GPa
@Strain 4.47 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 1.75 GPa
@Strain 0.11 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 1.76 GPa
@Strain 4.64 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 1.77 GPa
@Strain 3.76 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 1.78 GPa
@Strain 0.1 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 1.85 GPa
@Strain 0.17 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 1.875 GPa
@Strain 0.04 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 2.13 GPa
@Strain 0.2 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 2.14 GPa
@Strain 0.2 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 2.15 GPa
@Strain 0.06 %,
Temperature 23.0 °C
50%RH; ISO 11403-1 -2
 2.15 GPa
@Strain 2.18 %,
Temperature -20.0 °C
50%RH; ISO 11403-1 -2
 2.21 GPa
@Strain 0.23 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 2.22 GPa
@Strain 1.68 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 2.28 GPa
@Strain 1.93 %,
Temperature -40.0 °C
50%RH; ISO 11403-1 -2
 2.30 GPa
@Strain 0.23 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 2.40 GPa
@Strain 0.02 %,
Temperature -40.0 °C
DAM; ISO 11403-1 -2
 2.41 GPa
@Strain 0.14 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 2.43 GPa
@Strain 0.18 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 2.428 GPa
@Strain 0.5 %,
Temperature -20.0 °C
DAM; ISO 11403-1 -2
 2.59 GPa
@Strain 0.11 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
 2.78 GPa
@Strain 0.05 %,
Temperature 0.000 °C
50%RH; ISO 11403-1 -2
 2.83 GPa
@Strain 0.06 %,
Temperature 23.0 °C
DAM; ISO 11403-1 -2
 4.65 GPa
@Strain 0.02 %,
Temperature 0.000 °C
DAM; ISO 11403-1 -2
Charpy Impact Unnotched NBDAM; ISO 179/1eU
 NB50%RH; ISO 179/1eU
 NB
@Temperature -30.0 °C
DAM; ISO 179/1eU
 NB
@Temperature -30.0 °C
50%RH; ISO 179/1eU
Charpy Impact, Notched 5.00 kJ/m²DAM; ISO 179/1eA
 10.0 kJ/m²50%RH; ISO 179/1eA
 5.00 kJ/m²
@Temperature -30.0 °C
50%RH; ISO 179/1eA
 8.00 kJ/m²
@Temperature -30.0 °C
DAM; ISO 179/1eA
 
Thermal PropertiesOriginal ValueComments
CTE, linear, Parallel to Flow 110 µm/m-°CDAM; ISO 11359-1/-2
CTE, linear, Transverse to Flow 115 µm/m-°CDAM; ISO 11359-1/-2
Melting Point 203 °CDAM; 10°C/min; ISO 11357-1/-3
Flammability, UL94 HB
@Thickness 1.50 mm
DAM; IEC 60695-11-10
 HB
@Thickness 3.00 mm
DAM; IEC 60695-11-10
 
Descriptive Properties
Delivery formPellets
Part Marking Code>PA1010<ISO 11469
ProcessingOther Extrusion
 Profile Extrusion
Regional AvailabilityAsia Pacific
 Europe
 Global
 Near East/Africa
 North America
 South and Central America
Resin IdentificationPA1010ISO 1043
Special characteristicsHeat stabilized or stable to heat
 U.V. stabilized or stable to weather

**
Materials flagged as discontinued () are no longer part of the manufacturer’s standard product line according to our latest information. These materials may be available by special order, in distribution inventory, or reinstated as an active product. Data sheets from materials that are no longer available remain in MatWeb to assist users in finding replacement materials.

Users of our Advanced Search (registration required) may exclude discontinued materials from search results.

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to go back to viewing the property data in MatWeb's normal format.

Users viewing this material also viewed the following:
Celanese Zytel® RS LC1000 BK385 Nylon 1010
Evonik Vestamid® Terra DS 22 natural color Nylon 1010
Suzhou Hipro Polymers Hiprolon® 200 NN Nylon 1010, dry
Suzhou Hipro Polymers Hiprolon® 200 NN Nylon 1010, conditioned
PTS Trimid® N6-200L Nylon 6 with Lube

PZDSY5479a / 234773

Proto3000 – 3D Engineering Solutions

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.