Physical Properties | Original Value | Comments |
---|
Density | 8.95 g/cc |
|
Mechanical Properties | Original Value | Comments |
---|
Hardness, Brinell | 60 |
Tensile Strength, Ultimate | 240 MPa |
| 210 MPa @Temperature 230 °C |
| 230 MPa @Temperature 120 °C |
| 270 MPa @Temperature 25.0 °C |
| 295 MPa @Temperature -40.0 °C |
Tensile Strength, Yield | 125 MPa @Strain 0.5 % |
| 95.0 MPa @Strain 0.2 %, Temperature 120 °C |
| 95.0 MPa @Strain 0.2 %, Temperature 230 °C |
| 105 MPa @Strain 0.5 %, Temperature 120 °C |
| 105 MPa @Strain 0.5 %, Temperature 230 °C |
| 115 MPa @Strain 0.2 %, Temperature 25.0 °C |
| 125 MPa @Strain 0.5 %, Temperature 25.0 °C |
| 135 MPa @Strain 0.2 %, Temperature -40.0 °C |
| 145 MPa @Strain 0.5 %, Temperature -40.0 °C |
Elongation at Break | 20 % |
| 16 % @Temperature 230 °C |
| 22 % @Temperature 120 °C |
| 28 % @Temperature -40.0 °C |
| 30 % @Temperature 25.0 °C |
Reduction of Area | 20 % @Temperature 230 °C |
| 24 % @Temperature 25.0 °C |
| 26 % @Temperature -40.0 °C |
| 27 % @Temperature 120 °C |
Creep Strength | 12.0 MPa @Temperature 288 °C |
| 51.0 MPa @Temperature 232 °C |
| 71.7 MPa @Temperature 177 °C |
Rupture Strength | 120 MPa @Temperature 230 °C, Time 2.70e+6 sec |
| 135 MPa @Temperature 230 °C, Time 1.08e+6 sec |
| 150 MPa @Temperature 230 °C, Time 234000 sec |
| 210 MPa @Temperature 175 °C, Time 86400 sec |
Tensile Modulus | 11000 ksi |
| 45.0 GPa @Temperature 230 °C |
| 68.0 GPa @Temperature 120 °C |
| 82.0 GPa @Temperature 25.0 °C |
| 93.0 GPa @Temperature -40.0 °C |
Compressive Strength | 90.0 MPa |
| 325 MPa |
| 95.0 MPa @Temperature 120 °C |
| 100 MPa @Temperature 240 °C |
| 105 MPa @Temperature 25.0 °C |
| 120 MPa @Temperature 120 °C |
| 120 MPa @Temperature 240 °C |
| 140 MPa @Temperature -40.0 °C |
| 150 MPa @Temperature 25.0 °C |
| 175 MPa @Temperature -40.0 °C |
| 215 MPa @Temperature 25.0 °C |
| 270 MPa @Temperature 120 °C |
| 275 MPa @Temperature 240 °C |
| 350 MPa @Temperature -40.0 °C |
Fatigue Strength | 90.0 MPa @# of Cycles 1.00e+8 |
Machinability | 80 % |
Izod Impact | 7.00 J |
Charpy Impact | 15.0 J |
|
Electrical Properties | Original Value | Comments |
---|
Electrical Resistivity | 0.0000170 ohm-cm |
| 0.0000171 ohm-cm @Temperature 25.0 °C |
| 0.00001776 ohm-cm @Temperature 65.0 °C |
| 0.000018125 ohm-cm @Temperature 90.0 °C |
| 0.00001851 ohm-cm @Temperature 120 °C |
| 0.00001891 ohm-cm @Temperature 150 °C |
| 0.00001933 ohm-cm @Temperature 175 °C |
| 0.00001977 ohm-cm @Temperature 210 °C |
| 0.0000200 ohm-cm @Temperature 235 °C |
Magnetic Permeability | 1.0 |
|
Thermal Properties | Original Value | Comments |
---|
CTE, linear | 17.8 µm/m-°C @Temperature 100 °C |
| 18.0 µm/m-°C @Temperature 130 °C |
| 18.2 µm/m-°C @Temperature 165 °C |
| 18.3 µm/m-°C @Temperature 185 °C |
| 18.4 µm/m-°C @Temperature 215 °C |
| 18.6 µm/m-°C @Temperature 235 °C |
| 18.7 µm/m-°C @Temperature 270 °C |
Specific Heat Capacity | 0.376 J/g-°C |
Thermal Conductivity | 46.9 W/m-K @Temperature 20.0 °C |
| 47.0 W/m-K @Temperature 20.0 °C |
| 48.0 W/m-K @Temperature 40.0 °C |
| 50.0 W/m-K @Temperature 70.0 °C |
| 51.0 W/m-K @Temperature 95.0 °C |
| 52.0 W/m-K @Temperature 125 °C |
| 54.0 W/m-K @Temperature 160 °C |
| 56.0 W/m-K @Temperature 175 °C |
| 59.0 W/m-K @Temperature 205 °C |
| 62.0 W/m-K @Temperature 230 °C |
Melting Point | 762 - 930 °C |
Solidus | 762 °C |
Liquidus | 930 °C |
Shrinkage | 1.1 % |
|
Processing Properties | Original Value | Comments |
---|
Annealing Temperature | 260 °C |
|
Component Elements Properties | Original Value | Comments |
---|
Aluminum, Al | <= 0.0050 % |
Antimony, Sb | <= 0.50 % |
Copper, Cu | 78 - 82 % |
Iron, Fe | <= 0.15 % |
Lead, Pb | 8.0 - 11 % |
Nickel, Ni | <= 0.70 % |
Phosphorus, P | <= 0.050 % |
Silicon, Si | <= 0.0030 % |
Sulfur, S | <= 0.080 % |
Tin, Sn | 9.0 - 11 % |
Zinc, Zn | <= 0.70 % |
Some of the values displayed above may have been converted from their original units and/or rounded in order to
display the information in a consistent format. Users requiring more precise data for scientific or engineering
calculations can click on the property value to see the original value as well as raw conversions to equivalent units.
We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding
error. We also ask that you refer to MatWeb's
terms of use regarding this information.