MatWeb - Material Property Data Advertise with MatWeb!     Register Now
Data sheets for over 180,000 metals, plastics, ceramics, and composites.
MatWeb - Material Property Data HOME  •   SEARCH  •   TOOLS  •   SUPPLIERS  •   FOLDERS  •   ABOUT US  •   FAQ  •   LOG IN    
Recently Viewed Materials (most recent at top)  

Login to see your most recently viewed materials here.

Or if you don't have an account with us yet, then click here to register.

  Searches:   Advanced  | Category  | Property  | Metals  | Trade Name  | Manufacturer  | Recently Viewed Materials
  

Master Bond adhesives

Melos Mecoline IS RDX 5234 F Radiation cross-linkable, flame retardant compound
Categories: Polymer; Thermoplastic

Material Notes: Radiation cross-linkable, flame retardant compound

Compound class: Insulation

Compound category: RDX

Flame retardant: Not flame retardant

Standards: SAE J1128 TXL, GXL and SXL; UL 3289, 3321; SAE J1127 STX and SGX; CSA AWM I A/B; CSA CL 1251, 1503

Typical applications: Motor lead wires for coil connections, class F motors and transformers, pumps, solenoids, Internal wiring of appliances, sensor wires, flexible battery cables and wire insulation of low voltage multicore cables for road vehicles.

Features: Flame retardant; Flexible at low temperatures; Oil resistant; Abrasion resistant; High temperature resistant; Flexible

Information provided by Melos

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.20 g/cc0.0434 lb/in³pressed plaques; DIN EN ISO 1183-1A
Melt Flow 4.1 g/10 min
@Load 5.00 kg,
Temperature 190 °C
4.1 g/10 min
@Load 11.0 lb,
Temperature 374 °F
DIN EN ISO7619-1
 
Mechanical PropertiesMetricEnglishComments
Hardness, Shore D 5050pressed plaques; DIN ISO 7619-1
Tensile Strength 15.0 MPa2180 psiextruded tapes; IEC 60811-501
 17.0 MPa2470 psicross-linked plaques or tapes, 120kGy; IEC 60811-501
 12.3 MPa
@Temperature 180 °C,
Time 605000 sec
1780 psi
@Temperature 356 °F,
Time 168 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 12.465 MPa
@Temperature 70.0 °C,
Time 14400 sec
1807.9 psi
@Temperature 158 °F,
Time 4.00 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 12.93 MPa
@Temperature 158 °C,
Time 7.78e+6 sec
1875 psi
@Temperature 316 °F,
Time 2160 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 13.275 MPa
@Temperature 50.0 °C,
Time 86400 sec
1925.4 psi
@Temperature 122 °F,
Time 24.0 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 14.52 MPa
@Temperature 158 °C,
Time 1.04e+7 sec
2106 psi
@Temperature 316 °F,
Time 2880 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
Elongation at Break 330 %330 %cross-linked plaques or tapes, 120kGy; IEC 60811-501
 500 %500 %extruded tapes; IEC 60811-501
 >= 30 %
@Temperature -55.0 °C
>= 30 %
@Temperature -67.0 °F
cross-linked plaques / tapes (100-150 kGy); IEC 60811-505
 <= 10 %
@Temperature 200 °C,
Time 900 sec
<= 10 %
@Temperature 392 °F,
Time 0.250 hour
Hot set test, Residual, 0.2 Mpa; IEC 60811-507
 30 %
@Temperature 200 °C,
Time 900 sec
30 %
@Temperature 392 °F,
Time 0.250 hour
Hot set test, under load, 0.2 Mpa; IEC 60811-507
 346.5 %
@Temperature 158 °C,
Time 1.04e+7 sec
346.5 %
@Temperature 316 °F,
Time 2880 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 371.5 %
@Temperature 158 °C,
Time 7.78e+6 sec
371.5 %
@Temperature 316 °F,
Time 2160 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 426.5 %
@Temperature 180 °C,
Time 605000 sec
426.5 %
@Temperature 356 °F,
Time 168 hour
cross-linked plaques / tapes, After ageing in air oven; IEC 60811-401
 492 %
@Temperature 50.0 °C,
Time 86400 sec
492 %
@Temperature 122 °F,
Time 24.0 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 499 %
@Temperature 70.0 °C,
Time 14400 sec
499 %
@Temperature 158 °F,
Time 4.00 hour
cross-linked plaques / tapes, Fluid IRM 902; IEC 60811-404
 
Electrical PropertiesMetricEnglishComments
Volume Resistivity 1.00e+15 ohm-cm1.00e+15 ohm-cmASTM D 257
Dielectric Constant 2.9
@Frequency 50 Hz
2.9
@Frequency 50 Hz
ASTM D150
Dielectric Strength 25.0 kV/mm635 kV/inASTM D 149
 
Thermal PropertiesMetricEnglishComments
Maximum Service Temperature, Air 150 °C302 °F
Minimum Service Temperature, Air -50.0 °C-58.0 °F
 
Processing PropertiesMetricEnglishComments
Processing Temperature 145 - 155 °C293 - 311 °FTool
 170 °C338 °FMaximum mass temperature
Zone 1 130 - 140 °C266 - 284 °F
Zone 2 140 - 150 °C284 - 302 °F
Zone 3 145 - 155 °C293 - 311 °F
Zone 4 145 - 155 °C293 - 311 °F
Zone 5 145 - 155 °C293 - 311 °F
Adapter Temperature 145 - 155 °C293 - 311 °F
Head Temperature 145 - 155 °C293 - 311 °F
Drying Temperature 60.0 °C140 °F
Dry Time 4.00 hour4.00 hour
Shelf Life 12.0 Month12.0 Month
 
Component Elements PropertiesMetricEnglishComments
Loss on Ignition(%) 27 %27 %ASTM D 2863 A

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PMELOS041 / 296148

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.