Akro-Plastic Akromid® A3 GF 30 FR natural (7087) Nylon 66, Glass Fiber, Flame Retardant
Categories: Polymer; Thermoplastic; Nylon (Polyamide PA); Nylon 66 (PA66); Nylon 66, Glass Fiber Filled, Flame Retardant

Material Notes: Flame Retardant Compound. V0 at 0.4 mm with optimized corrosion prevention. PA 6.6 GF 30 FR (40).

Information provided by Akro-Plastic GmbH

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesOriginal ValueComments
Density 1.37 g/ccISO 1183
Filler Content 30 %ISO 1172
Linear Mold Shrinkage, Flow 0.0010 - 0.0030 cm/cmISO 294-4
Linear Mold Shrinkage, Transverse 0.0070 - 0.0090 cm/cmISO 294-4
 
Mechanical PropertiesOriginal ValueComments
Tensile Strength at Break 100 MPa5 mm/min. Conditioned; ISO 527-2
 145 MPa5 mm/min. Dry as Molded; ISO 527-2
Elongation at Break 3.0 %5 mm/min. Dry as Molded; ISO 527-2
 4.0 %5 mm/min. Conditioned; ISO 527-2
Tensile Modulus 7600 MPa1 mm/min. Conditioned; ISO 527-2
 10000 MPa1 mm/min. Dry as Molded.; ISO 527-2
Charpy Impact Unnotched 79.0 kJ/m²
@Temperature 23.0 °C
Dry as Molded; ISO 179-1/1eA
 
Electrical PropertiesOriginal ValueComments
Dielectric Strength 15.0 kV/mm
@Thickness 1.00 mm
Conditioned; IEC 60243
 15.0 kV/mm
@Thickness 1.00 mm
Dry as Molded; IEC 60243
Comparative Tracking Index >= 600 VDry as Molded. Test solution A.; IEC 60112
Hot Wire Ignition, HWI >= 120 sec
@Thickness 0.800 mm
Conditioned; UL 746A
 >= 120 sec
@Thickness 0.400 mm
Conditioned; UL 746A
 >= 120 sec
@Thickness 1.60 mm
Conditioned; UL 746A
 >= 120 sec
@Thickness 3.20 mm
Conditioned; UL 746A
 >= 120 sec
@Thickness 0.400 mm
Dry as Molded; UL 746A
 >= 120 sec
@Thickness 1.60 mm
Dry as Molded; UL 746A
 >= 120 sec
@Thickness 3.20 mm
Dry as Molded; UL 746A
 >= 120 sec
@Thickness 0.800 mm
Dry as Molded; UL 746A
High Amp Arc Ignition, HAI >= 120 arcs
@Thickness 0.400 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 0.800 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 1.60 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 3.20 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 0.400 mm
Dry as Molded; UL 746A
 >= 120 arcs
@Thickness 0.800 mm
Dry as Molded; UL 746A
 >= 120 arcs
@Thickness 1.60 mm
Dry as Molded; UL 746A
 >= 120 arcs
@Thickness 3.20 mm
Dry as Molded; UL 746A
 
Thermal PropertiesOriginal ValueComments
Melting Point 260 °CDry as Molded. DES, 10°C/min; DIN EN 11357-1
Deflection Temperature at 0.46 MPa (66 psi) 261 °CDry as Molded; ISO 75
Deflection Temperature at 1.8 MPa (264 psi) 245 °CDry as Molded; ISO 75
UL RTI, Electrical 65.0 °C
@Thickness 0.400 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.400 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Dry as Molded; UL 746 B
UL RTI, Mechanical with Impact 65.0 °C
@Thickness 0.400 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.400 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Dry as Molded; UL 746 B
UL RTI, Mechanical without Impact 65.0 °C
@Thickness 0.400 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.400 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Dry as Molded; UL 746 B
Flammability, UL94 V-0
@Thickness 0.800 mm
Conditioned
 V-0
@Thickness 0.400 mm
Conditioned
 V-0
@Thickness 1.60 mm
Conditioned
 V-0
@Thickness 3.20 mm
Conditioned
 V-0
@Thickness 0.400 mm
Dry as Molded
 V-0
@Thickness 1.60 mm
Dry as Molded
 V-0
@Thickness 3.20 mm
Dry as Molded
 V-0
@Thickness 0.800 mm
Dry as Molded
Glow Wire Ignition Temperature 750 °C
@Thickness 0.400 mm
Conditioned; IEC 60695-2-13
 750 °C
@Thickness 0.800 mm
Conditioned; IEC 60695-2-13
 750 °C
@Thickness 1.60 mm
Conditioned; IEC 60695-2-13
 750 °C
@Thickness 3.20 mm
Conditioned; IEC 60695-2-13
 750 °C
@Thickness 0.400 mm
Dry as Molded; IEC 60695-2-13
 750 °C
@Thickness 0.800 mm
Dry as Molded; IEC 60695-2-13
 750 °C
@Thickness 1.60 mm
Dry as Molded; IEC 60695-2-13
 750 °C
@Thickness 3.20 mm
Dry as Molded; IEC 60695-2-13
Glow Wire Flammability Index 960 °C
@Thickness 0.400 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 0.800 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 1.60 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 3.20 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 0.400 mm
Dry as Molded; IEC 60695-2-12
 960 °C
@Thickness 0.800 mm
Dry as Molded; IEC 60695-2-12
 960 °C
@Thickness 1.60 mm
Dry as Molded; IEC 60695-2-12
 960 °C
@Thickness 3.20 mm
Dry as Molded; IEC 60695-2-12

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to go back to viewing the property data in MatWeb's normal format.

PAKRO9936 / 255593

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.