MatWeb - Material Property Data Advertise with MatWeb!     Register Now
Data sheets for over 180,000 metals, plastics, ceramics, and composites.
MatWeb - Material Property Data HOME  •   SEARCH  •   TOOLS  •   SUPPLIERS  •   FOLDERS  •   ABOUT US  •   FAQ  •   LOG IN    
Recently Viewed Materials (most recent at top)  

Login to see your most recently viewed materials here.

Or if you don't have an account with us yet, then click here to register.

  Searches:   Advanced  | Category  | Property  | Metals  | Trade Name  | Manufacturer  | Recently Viewed Materials
  
Ensinger PEI
3M 5680 Cold Shrink Silicone Rubber Termination Kits QT-III
Categories: Polymer; Thermoset; Silicone; Silicone Rubber

Material Notes: 3M™ Cold Shrink 5600 and 5680 Series QT-II Termination Kits contain one-piece silicone rubber terminations designed for concentric neutral (CN) cable. They meet the requirements of IEEE 48-1990 for Class I termination. In addition, they meet German standard VDA 0278 parts 5 & 100, British standard BS C-89, Spanish standard UNE 21-115-75 and Brazilian standard A-B-N-T-9314. Similar terminations using Cold Shrink technology meet French EdF standards HN 33-E-01. Data on foreign standards are available upon request. The 3M termination consists of a high dielectric constant (Hi-K) stress control tube insulated with a molded silicone skirted insulator. There is a four-skirt design rated 25/28 kV, and an eight-skirt design rated 35 kV. Cold Shrink QT-II terminations are provided in an expanded state, mounted on a removable inner supporting plastic core. As supplied in this prestretched condition the termination is ready for field installation. During installation the core is unwound, allowing the termination to shrink and form a tight seal. Collectively, these terminations kits accommodate cable primary insulation diameters from .632” to 2.75” (16-70 mm). These kits can be used to terminate the following concentric neutral (CN) power cables: #2 AWG to 1250 kcmil at 15 kV; #2 AWG to 1500 kcmil at 25 kV and #2 AWG to 2000 kcmil at 35 kV.

Information provided by 3M

Vendors:
Available Properties
  • Tensile Strength, Ultimate, ASTM D42-68, Silicone Rubber Insulator
  • Tensile Strength, Ultimate, ASTM D42-68, EPDM Rubber Hi-K Stress Control Tube
  • Dielectric Constant, ASTM D150-70, Silicone Rubber Insulator
  • Dielectric Constant, ASTM D150-70, Silicone Rubber Insulator
  • Dielectric Constant, ASTM D150-70, Silicone Rubber Insulator
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Constant, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dielectric Strength, ASTM D149-70, Silicone Rubber Insulator
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 400 V at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Dissipation Factor, ASTM D150-70, EPDM Rubber Hi-K Stress Control Tube, 3 kV at 60% Strain
  • Track Resistance, ASTM 2303-68, 2.5 kV, 10 k Ohms
  
Property Data

This page displays only the text
of a material data sheet.

To see MatWeb's complete data
sheet for this material (including
material property data, metal
compositions, material suppliers,
etc
), please click the button below.

Manufacturer Notes:
none

Category Notes
Plastic

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

 

Visit Zeus Inc. for PEEK Tubing
Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.