MatWeb - Material Property Data Advertise with MatWeb!     Register Now
Data sheets for over 180,000 metals, plastics, ceramics, and composites.
MatWeb - Material Property Data HOME  •   SEARCH  •   TOOLS  •   SUPPLIERS  •   FOLDERS  •   ABOUT US  •   FAQ  •   LOG IN    
Recently Viewed Materials (most recent at top)  

Login to see your most recently viewed materials here.

Or if you don't have an account with us yet, then click here to register.

  Searches:   Advanced  | Category  | Property  | Metals  | Trade Name  | Manufacturer  | Recently Viewed Materials
  
USP Class VI Adhesives
USP Class VI Approved Adhesives for Medical Device Applications
Master Bond’s biocompatible adhesives are designed to meet the needs of medical device manufacturers. Compounds withstand various types of sterilization methods.
Chevron Phillips K-Resin® CK02 Styrene-Butadiene Copolymer, Blow Molding Grade  (discontinued **)
Categories: Polymer; Thermoplastic; Styrene-Butadiene; Styrene-Butadiene Copolymer, SBC

Material Notes: Styrene-Butadiene Copolymer

Customer Benefits: CK02 is a blow molding SBC designed to provide a softer, tougher, more flexible container while retaining the clarity and gloss of bottles produced from KR05. Finished products have low stiffness, excellent clarity, high surface gloss, and excellent toughness. K-Resin provides integral handles and wide mouth containers.

Applications: Major applications include squeeze bottles, food containers, medical packaging, and toys.

Processing Recommendations:
Can be processed on extrusion blow, injection stretch, and injection blow. Extrusion: Recommended maximum melt temperature is 195°C. Injection: Recommended maximum melt temperature, 216°C. High shear and restrictive type screws tend to degrade the melt. Generally no need to dry resin.

Specification Data: FDA Regulation 21 CFR 177.1640; suitable for food contact. EEC Directive 90/128/EEC and all its amendments. USP Class VI-50.

Data provided by Chevron Phillips Chemical Company LP.

Ineos Styrolution acquired the K-Resin® product line from Chevron Phillips Chemical Company in 2016. This grade was previously discontinued.

Vendors:
Available Properties
  • Density, ASTM D792
  • Melt Flow, ASTM D1238
  • Hardness, Shore D, ASTM D2240
  • Tensile Strength, Yield, 2 in per min; ASTM D638; Test specimens were injection molded by ASTM D1897.
  • Elongation at Break, 2 in per min; ASTM D638; Test specimens were injection molded by ASTM D1897.
  • Flexural Yield Strength, ASTM D790, Test specimens were injection molded by ASTM D1897
  • Flexural Modulus, ASTM D790, Test specimens were injection molded by ASTM D1897
  • Izod Impact, Notched, ASTM D256
  • Instrumented Impact Total Energy, ASTM D3763
  • Deflection Temperature at 1.8 MPa (264 psi), ASTM D648
  • Vicat Softening Point, ASTM D1525
  • Gloss, 60°
  • Transmission, Visible
  • Processing Temperature
  • FDA, See notes for details.
  • USP Class VI
  
Property Data

This page displays only the text
of a material data sheet.

To see MatWeb's complete data
sheet for this material (including
material property data, metal
compositions, material suppliers,
etc
), please click the button below.

Manufacturer Notes:
Chevron Phillips Chemical Company LP; ChevronPhillips

Category Notes
Plastic

**
Materials flagged as discontinued () are no longer part of the manufacturer’s standard product line according to our latest information. These materials may be available by special order, in distribution inventory, or reinstated as an active product. Data sheets from materials that are no longer available remain in MatWeb to assist users in finding replacement materials.

Users of our Advanced Search (registration required) may exclude discontinued materials from search results.

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

 

USP Class VI Adhesives
USP Class VI Approved Adhesives for Medical Device Applications
Master Bond’s biocompatible adhesives are designed to meet the needs of medical device manufacturers. Compounds withstand various types of sterilization methods.
Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.