Chemically Resistant adhesives
Fujipoly Industries Sarcon® GR-m Gap Filler Pad
Categories: Polymer; Thermoset; Silicone

Material Notes: Sarcon GR-m is a highly formable, thermally conductive gel material (no electicity conductive) in a versatile sheet form that easily fits and adheres to most all shapes and sizes of components, and make reliable and complete physical contact. GR-Hm has a hardened top surface

Information provided by Fujipoly Industries

Vendors:
Available Properties
  • Specific Gravity, JIS-K-6220; ASTM D-792
  • Specific Gravity, JIS-K-6220, 120°C for 1,000 hrs
  • Specific Gravity, JIS-K-6220, 150°C for 1,000 hrs
  • Specific Gravity, JIS-K-6220, 60°C for 1,000 hrs with 90% RH
  • Specific Gravity, JIS-K-6220, 70°C for 1,000 hrs
  • Hardness, Shore C, SRIS0101, 60°C for 1,000 hrs with 90% RH
  • Hardness, Shore C, SRIS0101, 70°C for 1,000 hrs
  • Hardness, Shore C, SRIS0101, 120°C for 1,000 hrs
  • Hardness, Shore C, SRIS0101, 150°C for 1,000 hrs
  • Hardness, Shore OO, SRIS0101; ASTM D-2240
  • Tensile Strength, Yield, JIS-K-6251(#2), 60°C for 1,000 hrs with 90% RH
  • Tensile Strength, Yield, JIS-K-6251(#2), 70°C for 1,000 hrs
  • Tensile Strength, Yield, JIS-K-6251(#2)/ASTM D-412
  • Tensile Strength, Yield, JIS-K-6251(#2), 120°C for 1,000 hrs
  • Tensile Strength, Yield, JIS-K-6251(#2), 150°C for 1,000 hrs
  • Elongation at Yield, JIS-K-6251(#2), 150°C for 1,000 hrs
  • Elongation at Yield, JIS-K-6251(#2), 70°C for 1,000 hrs
  • Elongation at Yield, JIS-K-6251(#2), 120°C for 1,000 hrs
  • Elongation at Yield, JIS-K-6251(#2), 60°C for 1,000 hrs with 90% RH
  • Elongation at Yield, JIS-K-6251(#2)/ASTM D-412
  • Tear Strength, JIS-K-6252, 60°C for 1,000 hrs with 90% RH
  • Tear Strength, JIS-K-6252 (Angle), 120°C for 1,000 hrs
  • Tear Strength, JIS-K-6252 (Angle), 70°C for 1,000 hrs
  • Tear Strength, JIS-K-6252 (Angle)/ASTM D-624
  • Tear Strength, JIS-K-6252 (Angle), 150°C for 1,000 hrs
  • Volume Resistivity, JIS-K-6249, 120°C for 1,000 hrs
  • Volume Resistivity, JIS-K-6249, 60°C for 1,000 hrs with 90% RH
  • Volume Resistivity, JIS-K-6249, 70°C for 1,000 hrs
  • Volume Resistivity, JIS-K-6249, 150°C for 1,000 hrs
  • Volume Resistivity, JIS-K-6249/ASTM D257
  • Dielectric Strength, JIS-K-6249, 70°C for 1,000 hrs
  • Dielectric Strength, JIS-K-6249; ASTM D-149
  • Dielectric Strength, JIS-K-6249, 150°C for 1,000 hrs
  • Dielectric Strength, JIS-K-6249, 60°C for 1,000 hrs with 90% RH
  • Dielectric Strength, JIS-K-6249, 120°C for 1,000 hrs
  • Dielectric Breakdown, JIS-K-6249; ASTM D-149, Withstand Voltage [V/min]
  • Thermal Conductivity, JIS-R-2618; ASTM D2326
  • Thermal Conductivity, JIS-R-2618, 120°C for 1,000 hrs
  • Thermal Conductivity, JIS-R-2618, 150°C for 1,000 hrs
  • Thermal Conductivity, JIS-R-2618, 60°C for 1,000 hrs with 90% RH
  • Thermal Conductivity, JIS-R-2618, 70°C for 1,000 hrs
  • Maximum Service Temperature, Air
  • Minimum Service Temperature, Air
  
Property Data

This page displays only the text
of a material data sheet.

To see MatWeb's complete data
sheet for this material (including
material property data, metal
compositions, material suppliers,
etc
), please click the button below.

Manufacturer Notes:
none

Category Notes
Plastic

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

 

Chemically Resistant adhesives
Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.