Master Bond adhesives

Ascend Performance Materials Vydyne® ECO515H NT0867 PA66-GF15 FR  (discontinued **)
Categories: Polymer; Thermoplastic; Nylon (Polyamide PA); Nylon 66 (PA66); Nylon 66, Glass Fiber Filled, Flame Retardant

Material Notes: Vydyne ECO515H NT0867 is a non-halogenated flame retardant, 15% glass fiber, heat stabilized PA66. ECO515H NT0867 has improved stiffness and strength.

Information provided by Ascend Performance Materials.

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.32 g/cc0.0477 lb/in³DAM; ISO 1183
Water Absorption 2.1 %
@Temperature 23.0 °C,
Time 86400 sec
2.1 %
@Temperature 73.4 °F,
Time 24.0 hour
DAM; ISO 62
Moisture Absorption at Equilibrium 1.7 %
@Temperature 23.0 °C
1.7 %
@Temperature 73.4 °F
DAM; ISO 62
Linear Mold Shrinkage, Flow 0.0040 cm/cm
@Thickness 2.00 mm
0.0040 in/in
@Thickness 0.0787 in
DAM; ISO 294-4
Linear Mold Shrinkage, Transverse 0.0080 cm/cm
@Thickness 2.00 mm
0.0080 in/in
@Thickness 0.0787 in
DAM; ISO 294-4
 
Mechanical PropertiesMetricEnglishComments
Tensile Strength at Break 66.0 MPa9570 psi50% RH; ISO 527-2
 100 MPa14500 psiDAM; ISO 527-2
Elongation at Break 3.2 %3.2 %DAM; ISO 527-2
 5.5 %5.5 %50% RH; ISO 527-2
Tensile Modulus 4.50 GPa653 ksi50% RH; ISO 527-2
 6.70 GPa972 ksiDAM; ISO 527-2
Flexural Strength 83.0 MPa12000 psi50% RH; ISO 178
 160 MPa23200 psiDAM; ISO 178
Flexural Modulus 4.30 GPa624 ksi50% RH; ISO 178
 6.70 GPa972 ksiDAM; ISO 178
Poissons Ratio 0.360.36ISO 527-2
Izod Impact, Notched (ISO)  6.30 kJ/m²
@Temperature -40.0 °C
3.00 ft-lb/in²
@Temperature -40.0 °F
50% RH; ISO 180/1A
 6.30 kJ/m²
@Temperature -40.0 °C
3.00 ft-lb/in²
@Temperature -40.0 °F
DAM; ISO 180/1A
 6.40 kJ/m²
@Temperature -30.0 °C
3.05 ft-lb/in²
@Temperature -22.0 °F
50% RH; ISO 180/1A
 7.20 kJ/m²
@Temperature 23.0 °C
3.43 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 180/1A
 7.20 kJ/m²
@Temperature -30.0 °C
3.43 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 180/1A
 9.70 kJ/m²
@Temperature 23.0 °C
4.62 ft-lb/in²
@Temperature 73.4 °F
50% RH; ISO 180/1A
Charpy Impact Unnotched  4.90 J/cm²
@Temperature -30.0 °C
23.3 ft-lb/in²
@Temperature -22.0 °F
50% RH; ISO 179/1eU
 4.90 J/cm²
@Temperature -40.0 °C
23.3 ft-lb/in²
@Temperature -40.0 °F
50% RH; ISO 179/1eU
 5.30 J/cm²
@Temperature -30.0 °C
25.2 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 179/1eU
 5.30 J/cm²
@Temperature -40.0 °C
25.2 ft-lb/in²
@Temperature -40.0 °F
DAM; ISO 179/1eU
 5.40 J/cm²
@Temperature 23.0 °C
25.7 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 179/1eU
 5.90 J/cm²
@Temperature 23.0 °C
28.1 ft-lb/in²
@Temperature 73.4 °F
50% RH; ISO 179/1eU
Charpy Impact, Notched  0.590 J/cm²
@Temperature -30.0 °C
2.81 ft-lb/in²
@Temperature -22.0 °F
50% RH; ISO 179/1eA
 0.590 J/cm²
@Temperature -40.0 °C
2.81 ft-lb/in²
@Temperature -40.0 °F
50% RH; ISO 179/1eA
 0.610 J/cm²
@Temperature -40.0 °C
2.90 ft-lb/in²
@Temperature -40.0 °F
DAM; ISO 179/1eA
 0.620 J/cm²
@Temperature -30.0 °C
2.95 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 179/1eA
 0.830 J/cm²
@Temperature 23.0 °C
3.95 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 179/1eA
 1.00 J/cm²
@Temperature 23.0 °C
4.76 ft-lb/in²
@Temperature 73.4 °F
50% RH; ISO 179/1eA
 
Electrical PropertiesMetricEnglishComments
Dielectric Strength  27.0 kV/mm
@Thickness 1.00 mm
686 kV/in
@Thickness 0.0394 in
50% RH; IEC 60243
 30.0 kV/mm
@Thickness 1.00 mm
762 kV/in
@Thickness 0.0394 in
DAM; IEC 60243
High Voltage Arc Resistance to Ignition (HVAR)  >= 120 sec
@Thickness 0.750 mm
>= 120 sec
@Thickness 0.0295 in
UL 746
 >= 120 sec
@Thickness 1.50 mm
>= 120 sec
@Thickness 0.0591 in
UL 746
 >= 120 sec
@Thickness 3.00 mm
>= 120 sec
@Thickness 0.118 in
UL 746
High Amp Arc Ignition, HAI  >= 120 arcs
@Thickness 0.400 mm
>= 120 arcs
@Thickness 0.0157 in
UL 746
 >= 120 arcs
@Thickness 0.750 mm
>= 120 arcs
@Thickness 0.0295 in
UL 746
 >= 120 arcs
@Thickness 1.50 mm
>= 120 arcs
@Thickness 0.0591 in
UL 746
 >= 120 arcs
@Thickness 3.00 mm
>= 120 arcs
@Thickness 0.118 in
UL 746
 
Thermal PropertiesMetricEnglishComments
CTE, linear, Parallel to Flow 30.0 µm/m-°C
@Thickness 2.00 mm,
Temperature 23.0 - 55.0 °C
16.7 µin/in-°F
@Thickness 0.0787 in,
Temperature 73.4 - 131 °F
DAM; ISO 11359-2
CTE, linear, Transverse to Flow 87.0 µm/m-°C
@Thickness 2.00 mm,
Temperature 23.0 - 55.0 °C
48.3 µin/in-°F
@Thickness 0.0787 in,
Temperature 73.4 - 131 °F
DAM; ISO 11359-2
Melting Point 260 °C500 °FDAM; ISO 11357-3
Deflection Temperature at 0.46 MPa (66 psi) 247 °C477 °FUnannealed; 50% RH; ISO 75-2/B
 250 °C482 °FUnannealed; DAM; ISO 75-2/B
Deflection Temperature at 1.8 MPa (264 psi) 216 °C421 °FUnannealed; 50% RH; ISO 75-2/A
 222 °C432 °FUnannealed; DAM; ISO 75-2/A
UL RTI, Electrical  140 °C
@Thickness 0.200 mm
284 °F
@Thickness 0.00787 in
UL 746
 140 °C
@Thickness 0.400 mm
284 °F
@Thickness 0.0157 in
UL 746
 140 °C
@Thickness 0.750 mm
284 °F
@Thickness 0.0295 in
UL 746
 140 °C
@Thickness 1.50 mm
284 °F
@Thickness 0.0591 in
UL 746
 140 °C
@Thickness 3.00 mm
284 °F
@Thickness 0.118 in
UL 746
UL RTI, Mechanical with Impact  110 °C
@Thickness 0.200 mm
230 °F
@Thickness 0.00787 in
UL 746
 115 °C
@Thickness 0.400 mm
239 °F
@Thickness 0.0157 in
UL 746
 130 °C
@Thickness 0.750 mm
266 °F
@Thickness 0.0295 in
UL 746
 130 °C
@Thickness 1.50 mm
266 °F
@Thickness 0.0591 in
UL 746
 140 °C
@Thickness 3.00 mm
284 °F
@Thickness 0.118 in
UL 746
UL RTI, Mechanical without Impact  120 °C
@Thickness 0.200 mm
248 °F
@Thickness 0.00787 in
UL 746
 125 °C
@Thickness 0.400 mm
257 °F
@Thickness 0.0157 in
UL 746
 140 °C
@Thickness 0.750 mm
284 °F
@Thickness 0.0295 in
UL 746
 140 °C
@Thickness 1.50 mm
284 °F
@Thickness 0.0591 in
UL 746
 150 °C
@Thickness 3.00 mm
302 °F
@Thickness 0.118 in
UL 746
Flammability, UL94  V-0
@Thickness 0.200 mm
V-0
@Thickness 0.00787 in
UL 94
 V-0
@Thickness 0.400 mm
V-0
@Thickness 0.0157 in
UL 94
 V-0
@Thickness 0.750 mm
V-0
@Thickness 0.0295 in
UL 94
 V-0
@Thickness 1.50 mm
V-0
@Thickness 0.0591 in
UL 94
 V-0
@Thickness 3.00 mm
V-0
@Thickness 0.118 in
UL 94
 5VA
@Thickness 1.50 mm
5VA
@Thickness 0.0591 in
UL 94
 5VA
@Thickness 3.00 mm
5VA
@Thickness 0.118 in
UL 94
 
Processing PropertiesMetricEnglishComments
Rear Barrel Temperature >= 275 °C>= 527 °FInjection
 <= 300 °C<= 572 °FInjection
Middle Barrel Temperature >= 275 °C>= 527 °FInjection
 <= 300 °C<= 572 °FInjection
Front Barrel Temperature >= 275 °C>= 527 °FInjection
 <= 300 °C<= 572 °FInjection
Nozzle Temperature >= 275 °C>= 527 °FInjection
 <= 300 °C<= 572 °FInjection
Melt Temperature >= 275 °C>= 527 °FInjection
 <= 300 °C<= 572 °FInjection
Mold Temperature >= 60.0 °C>= 140 °FInjection
 <= 120 °C<= 248 °FInjection
Drying Temperature <= 80.0 °C<= 176 °FInjection
 >= 80.0 °C>= 176 °FInjection
Dry Time >= 4.00 hour>= 4.00 hourInjection
 <= 6.00 hour<= 6.00 hourInjection
Moisture Content <= 0.20 %<= 0.20 %Injection
 
Descriptive Properties
AdditiveFlame Retarding Agent
 Heat Stabilizer
 Lubricant
Agency RatingsASTM, D4066 PA0120A2227
 ASTM, D6779 PA0120A2227
 ISO, 1043 PA66 GF15 FR(40)
AppearanceNatural Color
FeaturesCorrosion Resistant
 Electrical Corrosion Resistant
 Fast Molding Cycle
 Flame Retardant
 Good Colorability
 Good Dimensional Stability
 Good Electrical Properties
 Good Processability
 Good Strength
 Heat Aging Resistant
 Heat Stabilized
 High Flow
 Low Density
 Lubricated
FormsPellets
Processing MethodInjection Molding
Suggested Max Regrind (%)50Injection

**
Materials flagged as discontinued () are no longer part of the manufacturer’s standard product line according to our latest information. These materials may be available by special order, in distribution inventory, or reinstated as an active product. Data sheets from materials that are no longer available remain in MatWeb to assist users in finding replacement materials.

Users of our Advanced Search (registration required) may exclude discontinued materials from search results.

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PZASCE8496 / 318006

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.