Master Bond adhesives

Radici RADIFLAM® S FR 100 NT PBT, Flame Retardant, Dry
Categories: Polymer; Thermoplastic; Polyester, TP; Polybutylene Terephthalate (PBT); Polybutylene Terephthalate (PBT), Flame Retardant

Material Notes: Description: PA6 flame retardant injection molding grade. Halogen and phosphorus free. Natural color. Suitable for parts where fire retardancy is required. Rated V-0 at 0.4 mm according to UL-94.

Processing: Injection Molding

Delivery Form: Granules

Additives: Release agent , Flame retarding agent

Special Characteristics: Flame Retardant, Halogen-free, Heat stabilized or stable to heat, UL Listed, Railway Application

Industries: Consumer Industry Goods, Electrical and Electronical, Transportation

Regional Availability: North America, Europe, Asia Pacific, South and Central America, Near East/Africa

Information provided by Radici Group

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.17 g/cc0.0423 lb/in³ISO 1183
Water Absorption 8.0 %
@Thickness 2.00 mm
8.0 %
@Thickness 0.0787 in
Immersion at 23°C; ISO 62
Moisture Absorption 2.00 %
@Thickness 2.00 mm
2.00 %
@Thickness 0.0787 in
50% RH; ISO 62
Linear Mold Shrinkage, Flow 0.010 cm/cm0.010 in/inMelt Temp/Mold Temp/Cavity Pressure: 270/70/60; ISO 294-4
Linear Mold Shrinkage, Transverse 0.010 cm/cm0.010 in/inMelt Temp/Mold Temp/Cavity Pressure: 270/70/60; ISO 294-4
 
Mechanical PropertiesMetricEnglishComments
Tensile Strength, Yield 75.0 MPa10900 psi50 mm/min; ISO 527-2/1A
Elongation at Yield 4.0 %4.0 %50 mm/min; ISO 527-2/1A
Tensile Modulus 3.55 GPa515 ksi1mm/min; ISO 527-2/1A
Flexural Strength 110 MPa16000 psi2mm/min; ISO 178
Flexural Modulus 0.330 GPa47.9 ksi2mm/min; ISO 178
Charpy Impact, Notched  0.240 J/cm²
@Temperature -30.0 °C
1.14 ft-lb/in²
@Temperature -22.0 °F
ISO 179/1eA
 0.350 J/cm²
@Temperature 23.0 °C
1.67 ft-lb/in²
@Temperature 73.4 °F
ISO 179/1eA
 
Electrical PropertiesMetricEnglishComments
Volume Resistivity 1.00e+13 ohm-cm1.00e+13 ohm-cm500V; IEC 60093
Surface Resistance 1.00e+12 ohm1.00e+12 ohm500V; IEC 60093
Dielectric Strength 31.0 kV/mm787 kV/inIEC 60243-1
Comparative Tracking Index 600 V600 VSol. A; IEC 60112
 
Thermal PropertiesMetricEnglishComments
Melting Point 220 °C428 °FISO 11357-1/-3
Deflection Temperature at 0.46 MPa (66 psi) 160 °C320 °FISO 75/2Bf
Deflection Temperature at 1.8 MPa (264 psi) 55.0 °C131 °FISO 75/2Af
Vicat Softening Point 195 °C
@Load 5.10 kg
383 °F
@Load 11.2 lb
50°C/h; ISO 306
Flammability, UL94  V-0
@Thickness 0.400 mm
V-0
@Thickness 0.0157 in
 V-0
@Thickness 0.800 mm
V-0
@Thickness 0.0315 in
Flame Spread 0.000 mm/min
@Thickness 3.00 mm
0.000 in/min
@Thickness 0.118 in
Automotive Interior; ISO 3795
Oxygen Index 36 %36 %Limiting; ISO 4589-2
Glow Wire Ignition Temperature  800 °C
@Thickness 1.00 mm
1470 °F
@Thickness 0.0394 in
IEC 60695-2-13
 800 °C
@Thickness 2.00 mm
1470 °F
@Thickness 0.0787 in
IEC 60695-2-13
Glow Wire Flammability Index  960 °C
@Thickness 1.00 mm
1760 °F
@Thickness 0.0394 in
IEC 60695-2-12
 960 °C
@Thickness 2.00 mm
1760 °F
@Thickness 0.0787 in
IEC 60695-2-12
 
Processing PropertiesMetricEnglishComments
Melt Temperature 240 - 280 °C464 - 536 °F
Mold Temperature 70.0 - 80.0 °C158 - 176 °F

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PRADICI055 / 313556

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.