MatWeb - Material Property Data Advertise with MatWeb!     Register Now
Data sheets for over 180,000 metals, plastics, ceramics, and composites.
MatWeb - Material Property Data HOME  •   SEARCH  •   TOOLS  •   SUPPLIERS  •   FOLDERS  •   ABOUT US  •   FAQ  •   LOG IN    
Recently Viewed Materials (most recent at top)  

Login to see your most recently viewed materials here.

Or if you don't have an account with us yet, then click here to register.

  Searches:   Advanced  | Category  | Property  | Metals  | Trade Name  | Manufacturer  | Recently Viewed Materials
  
USP Class VI Adhesives
USP Class VI Approved Adhesives for Medical Device Applications
Master Bond’s biocompatible adhesives are designed to meet the needs of medical device manufacturers. Compounds withstand various types of sterilization methods.
INEOS Styrolution K-Resin® DK11 Styrene-Butadiene Copolymer, Film Grade  (Unverified Data**)
Categories: Polymer; Film; Thermoplastic; Styrene-Butadiene; Styrene-Butadiene Copolymer, SBC

Material Notes: Styrene-Butadiene Copolymer. Properties below based on 1 mil ( 0.025 mm) film; 2.5:1 Blow Up Ratio; 35 mil (0.90 mm) die gap.

Customer Benefits: Provides the same high performance film properties as KR10 with added thermal stability and a broader processing window. Film produced has excellent clarity, high surface gloss, good heat sealability, good toughness, good stiffness, and high permeation. Has a puncture value of 1.2 J as per ASTM D3763. Has a crease retention of 99% as per TAPPI T446-B. Also has a moisture vapor transmission value of 0.6 g mm/m^2 24hr as per ASTM F1249 at 23°C. Film shrinkage is 67% MD and 48% TD.

Applications: Major applications include medical packaging, produce packaging, skin packaging, twist wrap, lidstock film, labeling film, decorative films, industrial films, shrink wrap, overwrap film, barrier film, and tamper evident packaging

Processing Recommendations:
Blown Film: Melt temperature between 166-193°C recommended. Cast film: Melt temperature between 193-216°C recommended. High shear and restrictive type screws tend to degrade the melt.

Specification Data: FDA Regulation 21 CFR 177.1640. Suitable for food contact. EEC Directive 90/128/EEC and all its amendments. USP Class VI-50. UL 94HB.

Ineos Styrolution acquired the K-Resin® product line from Chevron Phillips Chemical Company in 2016.

Vendors:
Available Properties
  • Density, ASTM D792
  • Moisture Vapor Transmission, ASTM F1249, @ 23°C
  • Oxygen Transmission, ASTM D3985
  • Melt Flow, Condition G; ASTM D1238
  • Film Tensile Strength at Yield, MD, ASTM D882, 2 in per min
  • Film Tensile Strength at Yield, TD, ASTM D882, 2 in per min
  • Film Elongation at Break, MD, ASTM D882
  • Film Elongation at Break, TD, ASTM D882
  • Secant Modulus, MD, at 1%; ASTM D882
  • Secant Modulus, TD, at 1%; ASTM D882
  • Elmendorf Tear Strength, MD, ASTM D1922
  • Elmendorf Tear Strength, TD, ASTM D1922
  • Dart Drop Test, 26 in; ASTM D1709
  • Haze, ASTM D1003
  • Gloss, 45°; ASTM D2457
  • Transmission, Visible, ASTM D1003
  • Melt Temperature, Blown Film
  • FDA, See notes for details.
  • USP Class VI
  
Property Data

This page displays only the text
of a material data sheet.

To see MatWeb's complete data
sheet for this material (including
material property data, metal
compositions, material suppliers,
etc
), please click the button below.

Manufacturer Notes:
none

Category Notes
Plastic

**
This data sheet is not an active part of MatWeb and the information on it should not be considered reliable.
Inactive data sheets have usually been replaced with newer information on the same material. If this is the case, you can find the active data sheet by using any of our search tools, including the Quick Search box in the upper part of this page.
If you are unable to locate an active data sheet for this material, then this material is likely discontinued, although various other reasons may be behind its removal. In any event, do not rely on the information on this page to be accurate or maintained.
You may have reached this data sheet through an outdated bookmark or link. Please update your bookmark accordingly. We apologize if you have accessed this page through MatWeb’s usual search tools.

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

 

USP Class VI Adhesives
USP Class VI Approved Adhesives for Medical Device Applications
Master Bond’s biocompatible adhesives are designed to meet the needs of medical device manufacturers. Compounds withstand various types of sterilization methods.
Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.