Ensinger PEI

Celanese Zytel® HTNFR52G45NHF NC010 PA6T/66-GF45FR(40)
Categories: Polymer; Thermoplastic; Polyphthalamide (PPA); Polyphthalamide (PPA), 50% Glass Fiber Reinforced

Material Notes: 45% Glass Reinforced, Flame Retardant, Non-Halogenated, PPA, High Performance Polyamide

Former DuPont product acquired by Celanese in 2022.

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.60 g/cc0.0578 lb/in³DAM; ISO 1183
Linear Mold Shrinkage, Flow 0.0020 cm/cm0.0020 in/inDAM; ISO 294-4, 2577
Linear Mold Shrinkage, Transverse 0.0060 cm/cm0.0060 in/inDAM; ISO 294-4, 2577
 
Mechanical PropertiesMetricEnglishComments
Tensile Strength at Break 167 MPa24200 psiDAM; ISO 527-1/-2
Elongation at Break 1.7 %1.7 %DAM; ISO 527-1/-2
Tensile Modulus 15.5 GPa2250 ksiDAM; ISO 527-1/-2
Flexural Strength 249 MPa36100 psiDAM; ISO 178
Flexural Modulus 15.1 GPa2190 ksiDAM; ISO 178
Poissons Ratio 0.330.33DAM
Charpy Impact Unnotched  4.50 J/cm²
@Temperature -30.0 °C
21.4 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 179/1eU
 4.80 J/cm²
@Temperature 23.0 °C
22.8 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 179/1eU
Charpy Impact, Notched  0.800 J/cm²
@Temperature -30.0 °C
3.81 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 179/1eA
 0.800 J/cm²
@Temperature 23.0 °C
3.81 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 179/1eA
 
Electrical PropertiesMetricEnglishComments
Volume Resistivity >= 1.00e+15 ohm-cm>= 1.00e+15 ohm-cmDAM; IEC 62631-3-1
Dielectric Constant  4.4
@Frequency 1e+6 Hz
4.4
@Frequency 1e+6 Hz
DAM; IEC 62631-2-1
 4.7
@Frequency 100 Hz
4.7
@Frequency 100 Hz
DAM; IEC 62631-2-1
Dielectric Strength 40.0 kV/mm1020 kV/inDAM; IEC 60243-1
Dissipation Factor  0.0060
@Frequency 100 Hz
0.0060
@Frequency 100 Hz
DAM; IEC 62631-2-1
 0.0115
@Frequency 1e+6 Hz
0.0115
@Frequency 1e+6 Hz
DAM; IEC 62631-2-1
Comparative Tracking Index 600 V600 VDAM; IEC 60112
 
Thermal PropertiesMetricEnglishComments
CTE, linear, Parallel to Flow 15.0 µm/m-°C8.33 µin/in-°FDAM; ISO 11359-1/-2
 13.0 µm/m-°C
@Temperature -40.0 - 23.0 °C
7.22 µin/in-°F
@Temperature -40.0 - 73.4 °F
DAM; ISO 11359-1/-2
 14.0 µm/m-°C
@Temperature 55.0 - 160 °C
7.78 µin/in-°F
@Temperature 131 - 320 °F
DAM; ISO 11359-1/-2
CTE, linear, Transverse to Flow 50.0 µm/m-°C27.8 µin/in-°FDAM; ISO 11359-1/-2
 43.0 µm/m-°C
@Temperature -40.0 - 23.0 °C
23.9 µin/in-°F
@Temperature -40.0 - 73.4 °F
DAM; ISO 11359-1/-2
 80.0 µm/m-°C
@Temperature 55.0 - 160 °C
44.4 µin/in-°F
@Temperature 131 - 320 °F
DAM; ISO 11359-1/-2
Melting Point 310 °C590 °Ffirst heat; DAM; ISO 11357-1/-3
Deflection Temperature at 1.8 MPa (264 psi) 284 °C543 °FDAM; ISO 75-1/-2
Glass Transition Temp, Tg 45.0 °C113 °F10°C/min; 50% RH; ISO 11357-1/-2
 90.0 °C194 °F10°C/min; DAM; ISO 11357-1/-2
UL RTI, Electrical  140 °C
@Thickness 0.400 mm
284 °F
@Thickness 0.0157 in
UL 746B
 140 °C
@Thickness 0.750 mm
284 °F
@Thickness 0.0295 in
UL 746B
 140 °C
@Thickness 1.50 mm
284 °F
@Thickness 0.0591 in
UL 746B
 140 °C
@Thickness 3.00 mm
284 °F
@Thickness 0.118 in
UL 746B
Flammability, UL94 V-0
@Thickness 0.400 mm
V-0
@Thickness 0.0157 in
DAM; IEC 60695-11-10
Glow Wire Ignition Temperature  700 °C
@Thickness 0.400 mm
1290 °F
@Thickness 0.0157 in
DAM; IEC 60695-2-12
 750 °C
@Thickness 0.750 mm
1380 °F
@Thickness 0.0295 in
DAM; IEC 60695-2-13
 750 °C
@Thickness 1.50 mm
1380 °F
@Thickness 0.0591 in
DAM; IEC 60695-2-13
 800 °C
@Thickness 3.00 mm
1470 °F
@Thickness 0.118 in
DAM; IEC 60695-2-13
Glow Wire Flammability Index  960 °C
@Thickness 0.400 mm
1760 °F
@Thickness 0.0157 in
DAM; IEC 60695-2-12
 960 °C
@Thickness 0.750 mm
1760 °F
@Thickness 0.0295 in
DAM; IEC 60695-2-12
 960 °C
@Thickness 1.50 mm
1760 °F
@Thickness 0.0591 in
DAM; IEC 60695-2-12
 960 °C
@Thickness 3.00 mm
1760 °F
@Thickness 0.118 in
DAM; IEC 60695-2-12
 
Processing PropertiesMetricEnglishComments
Melt Temperature 320 - 325 °C608 - 617 °FRange, Injection
Mold Temperature 90.0 - 130 °C194 - 266 °FInjection
Drying Temperature 100 °C212 °FInjection
Dry Time 6.00 - 8.00 hour6.00 - 8.00 hourInjection, Dehumidified Dryer
Moisture Content <= 0.10 %<= 0.10 %Injection
 
Descriptive Properties
AdditivesFlame retardant
 Non-halogenated/Red phosphorous free flame retardant
Drying RecommendedyesInjection
ISO designationISO 16396-PA6T/66,GF45 FR(40),M1F1GN,S10-160
Part Marking Code>PA6T/66-GF45FR(40)<ISO 11469
 >PPA-GF45FR<SAE J1344
PolymerPA6T/66-GF45 FR(40)
Resin IdentificationPA6T/66-GF45FR(40)ISO 1043

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PDSX5466b / 291028

Proto3000 – 3D Engineering Solutions

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.